Water Quality Monitor PH Conductivity TDS Salinity Resistivity DO Temp Tester
$ 427.67
- Description
- Size Guide
Description
Water Quality Monitor PH Conductivity TDS Salinity Resistivity DO Temp TesterShippnig Policy :Battery /Liquid /Powder can not be included during the Shipping
High-performance multiparameter water quality meter contains the 8 measurement modes, the meter is suitable for measuring the pH, conductivity, TDS, salinity, resistivity and dissolved oxygen.
(If you want to measure ORP, ion concentration, you need to purchase additional electrodes, please contact us)
pH Mode:
• Portable multiparameter water quality meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and offset.
ORP Mode: (ORP Probe is optional,if you need please contact us)
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration Mode(Ion Probe is optional,if you need please contact us)
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Direct ion concentration readout simplifies the measurement process.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency.
Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement error.
Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Auto-Power Off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature
unit, date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to PC.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the
meter smoothly.
Specifications
Model
Bante900P
pH
Range
-2.000 to 20.000pH
Resolution
0.001, 0.01, 0.1pH, selectable
Accuracy
±0.002pH
Calibration Points
1 to 5 points
pH Buffer Options
USA, NIST, DIN, 2 custom buffers
ORP
Range
±1999.9mV
Resolution
0.1, 1mV, selectable
Accuracy
±0.2mV
Calibration Points
1 point
Measurement Modes
Relative or absolute mV
Ion Concentration
Range
0.001 to 19999 (deponding on the range of ISE)
Resolution
0.001, 0.01, 0.1, 1
Accuracy
±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Calibration Points
2 to 5 points
Calibration Solutions
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000
Measurement Units
ppm, mg/L, mol/L, mmol/L
Conductivity
Range
0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution
0.001, 0.01, 0.1, 1
Accuracy
±0.5% F.S.
Calibration Points
1 to 5 points
Calibration Solutions
10µS, 84µS, 1413µS, 12.88mS, 111.8mS
Temperature Coefficient
Linear (0.0 to 10.0%/°C), pure water
Reference Temperature
20/25°C
Cell Constant
K=0.1, 1, 10 or custom
TDS
Range
0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution
0.01, 0.1, 1
Accuracy
±1% F.S.
TDS Factor
0.1 to 1.0 (default 0.5)
Salinity
Range
0.00 to 80.00ppt, 0.00 to 42.00psu
Resolution
0.01
Accuracy
±1% F.S.
Resistivity
Range
0.00 to 20.00MΩ
Resolution
0.01
Accuracy
±1% F.S.
Dissolved Oxygen
DO Range
0.00 to 20.00mg/L
Resolution
0.01, 0.1mg/L, selectable
Accuracy
±0.2mg/L
% Saturation of Oxygen
0.0 to 200.0%
Resolution
0.1, 1%, selectable
Accuracy
±2.0%
Calibration Points
1 or 2 points
Pressure Correction
60.0 to 112.5kPa/450 to 850mmHg, manual
Salinity Correction
0.0 to 50.0g/L, manual
Temperature
Range
0 to 105°C/32 to 221°F
Resolution
0.1°C/0.1°F
Accuracy
±0.5°C/±0.9°F
Offset Calibration
1 point
Calibration Range
Reading ±10°C
General Specifications
Temperature Compensation
0 to 100°C/32 to 212°F, manual or automatic
Stability Criteria
Low or high
Calibration Due Alarm
1 to 31 days or off
Auto-Power Off
10, 20 or 30 minutes after last key pressed
Memory
Stores up to 500 data sets
Output
USB communication interface
Connector
BNC, 6-pin nimi-DIN, 3.5mm jack socket
Display
Custom LCD (80×60mm)
Power
3×1.5V AA batteries or DC5V power adapter
Battery Life
Approximately 150 hours (turn off the backlight)
Dimensions
170(L)×85(W)×30(H)mm
Weight
300g
Standard Packing :
E201-BNC pH electrode
CON-1 conductivity electrode
DO100 dissolved oxygen electrode
TP-10K temperature probe
DO membrane cap
Carrying case
Use manual